Fluke 1625 Kit Advanced GEO Earth Ground Tester Kit
$3,699.95
The
Fluke 1625 is intended for electrical utility or other high frequency
environments as it has extra versatility for more demanding
applications.
The Fluke 1625 is a distinctive earth ground tester that can perform all four types of earth ground measurement. Not only measure ground resistance using the classic 'fall of potential test' but also enable time saving testing using the 'selective' and 'stakeless' methods. 'Selective' testing does not require the electrode under test to be disconnected during the measurement, thus increasing safety. The simple 'stakeless' method quickly checks ground connections using two current transformers (probes) clamped around the ground conductor under test.
Testing Methods
The Fluke 1625 offers these advanced features:
Earth ground resistance and soil resistivity should be measured when:
The Fluke 1625 is the stand-alone unit
For a basic model see the Fluke 1623
The Fluke 1625 is a distinctive earth ground tester that can perform all four types of earth ground measurement. Not only measure ground resistance using the classic 'fall of potential test' but also enable time saving testing using the 'selective' and 'stakeless' methods. 'Selective' testing does not require the electrode under test to be disconnected during the measurement, thus increasing safety. The simple 'stakeless' method quickly checks ground connections using two current transformers (probes) clamped around the ground conductor under test.
Testing Methods
- 3- and 4-Pole Fall of Potential – standard earth ground testing using two ground stakes
- 4-Pole Soil Resistivity testing – determine soil resistivity using four ground stakes
- Selective testing – without disconnecting ground rods, a technician can measure ground resistance using a combination of stakes and a clamp.
- Stakeless testing – innovative solution using only clamps, instead of ground stakes, to measure earth ground loop resistance.
The Fluke 1625 offers these advanced features:
- Automatic Frequency Control (AFC) – identifies existing interference and chooses a measurement frequency to minimize its effect, providing a more accurate earth ground value.
- R* measurement – calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to-earth ground would see.
- Adjustable limits – for quick test result verification.
Earth ground resistance and soil resistivity should be measured when:
- Designing earth ground systems
- Installing new ground system and electrical equipment
- Periodically testing ground and lightning protection systems
- Installing large electrical equipment such as transformers, switchgears, machines, etc.
The Fluke 1625 is the stand-alone unit
For a basic model see the Fluke 1623
- Fluke 1625 tester
- 2 test leads
- 2 alligator clips
- 4 earth ground stakes
- 3 cable reels with wire (2-25 m, 1-50 m)
- selective/stakeless clamp set (one inducing, one sensing)
- Batteries
- Users manual
- Rugged carrying case
Share this item: